A completed two-story barndominium with visible second-story windows and a small covered balcony above the entry porch.

2-Story Barndominium in NC

Stacking is the standard answer to a lot-coverage cap and the standard way to run into a height cap, and in North Carolina both are county rules with genuinely different answers. Robeson County caps the principal building and all accessory buildings together at twenty percent of lot area; Stokes County caps the principal building at twenty percent; Madison County caps principal plus accessory at twenty percent; Cabarrus County caps impermeable surface at fifteen percent in its Agricultural/Open Space district; Buncombe County's steep-slope standards cap gross site disturbance at 0.3 acres on lots under two acres. Going up relieves every one of those. What it costs is height: the Davidson, Iredell, Stokes and Madison rural districts cap building height at 35 feet, Cabarrus at 40 feet, Sampson's Residential Agricultural district at 40 feet, and Henderson County's rural district sets no maximum height at all. The structural side is where a barndominium differs from a conventional two-storey house. Section R301.2.1 requires a continuous load path transmitting uplift from the roof assembly to the foundation, and that path is longer and has more joints in a stacked post-frame or steel building — which, under Section R301.1.2, is an other framing system required to show equivalent detailing rather than to follow a table.

What actually changes with this feature

The look is the easy part. These are the decisions that follow from it.

Height caps are county rules, and they are not uniform

Davidson County's Table of Dimensional Requirements gives the RA districts a 30,000 square foot minimum lot area on well and septic, 100 feet of lot width, a 30-foot front setback, 10-foot side, 20-foot rear and a maximum building height of 35 feet. Iredell County's Table 2.3 sets A-C Agricultural Conservation at 87,120 square feet per dwelling unit with a 35-foot height cap, and R-A carries the same cap. Stokes County caps height at 35 feet with a 40-foot front yard and 15-foot sides. Madison County caps at 35 feet on one acre with 20 percent maximum lot coverage. Cabarrus County's AO and CR districts run to 40 feet. Sampson County's RA allows 40 feet. Henderson County's rural district sets no maximum height and lets an accessory structure exceed the 15-foot accessory cap on lots of one acre or more. Read the district, not the region.

The load path is longer, and the code asks for it explicitly

Section R301.2.1 requires a continuous load path to transmit the applicable uplift forces from the roof assembly to the foundation. On a single-storey shell that path has one set of connections; on a stacked building it passes through a floor diaphragm, a rim condition and a second set of column-to-beam and beam-to-post connections, each of which has to be detailed. Section R301.1.2 is the governing sentence for a post-frame or steel frame: the code's requirements are based on platform and balloon-frame construction, and other framing systems must have equivalent detailing to ensure force transfer, continuity and compatible deformations. Section R301.1.3 permits engineered design for elements exceeding the limits of Section R301, or whole-building design to the International Building Code. Moore County's residential permit checklist states that metal buildings will require stamped engineer plans as per NCDOI guidance.

Wind is per county, and a second storey interacts with it oddly

The 2018 edition publishes ultimate design wind speed county by county in Table R301.2(4), and 51 of the 100 counties are unlisted and take the 115 mph default — including Wake, Mecklenburg, Guilford, Forsyth, Iredell, Cabarrus and Davidson Counties. Table R301.2(4) names Harnett County and Johnston County at 120 mph, Cumberland County at 120 mph west of I-95 and 130 mph east of it, and Carteret County at 150 mph. Twelve counties — Alleghany, Ashe, Avery, Buncombe, Graham, Haywood, Jackson, Madison, Mitchell, Swain, Watauga and Yancey — have no county figure at all: Table R301.2(5) sets the speed from the building's first-floor finish elevation, so adding a storey does not move a site up that ladder. What a second storey can cross is a different trigger. R905.2.6 requires six fasteners per asphalt strip shingle where Table R301.2(4) gives 130 mph or more and the eave is 20 feet or more above grade — and a second storey is what puts the eave over 20 feet.

How the second floor gets billed depends on the county's basis

Wake County charges $75 plus $0.25 per square foot of gross floor area, and the schedule defines the area measured as everything finished within the inside perimeter of the exterior walls with no deduction for garage, corridors, stairs or closets — so the upstairs circulation and the stair are inside the base. Guilford County charges $150 plus $0.35 per heated square foot in the area it inspects, so a heated second storey is billed in full while an unheated bay is not. Union County charges $0.84 per square foot on area under roof, heated or unheated, at 3.5 times its detached rate of $0.24. Wilkes County brackets heated area from $0.20 per square foot at 1,000 to 2,499 square feet up to $0.36 at 10,000 and above, so a second storey can push the whole building into the next bracket. Gaston County does not measure area at all: a $990 minimum for a new residential home, then ICC construction valuation or the stated contract price, whichever is greater.

A completed two-story barndominium with visible second-story windows and a small covered balcony above the entry porch.
Up instead of out, and what it moves

A second storey solves the coverage rule and meets the height rule

Halving the footprint is the cleanest way past a lot-coverage cap, and North Carolina counties write those caps in real numbers. Stokes County allows the principal building twenty percent of the lot; Madison County allows twenty percent for principal and accessory together; Robeson County the same for principal plus all accessory buildings in Residential-Agricultural; Cabarrus County holds impermeable surface to fifteen percent in Agricultural/Open Space; Buncombe County's steep-slope standards allow 0.3 acres of gross site disturbance on a lot under two acres and 0.16 acres of impervious surface, counting drives, utilities and stormwater controls alongside the building. Then the ceiling arrives. Davidson County's Table of Dimensional Requirements caps the RA districts at 35 feet; Iredell County caps A-C and R-A at 35 feet; Stokes and Madison Counties at 35 feet; Cabarrus County's AO and CR at 40 feet; Sampson County's RA at 40 feet, with 35-foot front, 10-foot side, 20-foot street-side and 25-foot rear setbacks. Henderson County's rural district sets no maximum height at all. A two-storey living end with a tall shop bay beside it can approach 35 feet faster than a conventional house does, so the cap is worth reading against the elevation drawing rather than after it.

Common ways to build this

Common configurations we see. Yours does not have to match one exactly — this is a starting point for the conversation, not a catalog.

Two-storey living end, single-storey shop bay

Two floors of living space at one end, a tall clear-span bay at the other

The arrangement most two-storey barndominiums land on, because it puts the height where the rooms are and leaves the bay as a single tall volume. Two things to check against the elevation. First the district cap: 35 feet in the Davidson, Iredell, Stokes and Madison rural districts, 40 feet in Cabarrus and in Sampson's RA — and a tall bay with an equipment door on one side of a two-storey ridge can be the part that reaches it. Second the fee basis, because the two volumes are billed differently depending on the county. Guilford County's rate touches only heated area, so the bay costs nothing; Wake County's gross-floor-area definition takes no deduction inside the exterior perimeter; Gaston County prices unheated space, garages, porches and decks on its Utility/Miscellaneous row.

Full second storey over the whole footprint

Bedrooms and baths upstairs, living and shop below

The best answer to a coverage cap and the sharpest test of the height cap. Halving the footprint halves what counts against Stokes County's twenty percent principal-building cap, Madison County's twenty percent, Robeson County's twenty percent for principal plus accessory, and Cabarrus County's fifteen percent impermeable limit in Agricultural/Open Space — and it reduces the graded area that counts toward Buncombe County's 0.3-acre gross site disturbance limit on a lot under two acres. It does not reduce the septic. Under 15A NCAC 18E the Improvement Permit fixes the design daily flow and the bedroom count, and .0508(b) requires space for both the initial dispersal field and a repair area regardless of how the house is stacked, so the drainfield and its spare occupy the same ground either way.

Loft or partial second floor over part of the plan

Open volume over the living space, enclosed rooms over the utility end

A partial upper floor is the configuration most likely to be mispriced, because the room it creates may or may not be a bedroom in the eyes of three different offices. Johnston County's permit checklist stresses that the bedrooms shown on the septic permit have to match the bedrooms in the residence. Guilford County charges the residential soil evaluation at $100 per bedroom and its permit guidance requires the bedroom count on the plans, the application and the septic design to agree, with a permit amendment when it changes. Chatham County prices the Improvement Permit at $150 for two bedrooms rising to $400 for six. Cabarrus County brackets the Construction Authorization by design flow — $350 at 360 gallons per day or less for one to three bedrooms, $450 at 600 gpd or less for four to five. A bonus room over the shop is a priced decision, so make it deliberately.

Two storeys into a slope, with a walk-out lower level

Lower level cut into grade, main level at the top of the slope

On sloping ground this gets the second floor without the full height above the ridge line, which matters where the cap is measured generously and where slope rules apply. Buncombe County's ridge and steep-slope standards are the clearest case: 25 feet maximum where the structure is 50 or fewer vertical feet below the crest and 35 feet where it is more than 50 below, plus a building width limit of 30 percent of lot width on the ridge protection side, and screening on structure faces oriented to a downhill section dropping 25 feet or more within 100 feet. Septic gets harder rather than easier on slope: 15A NCAC 18E .0502 makes a uniform stable slope suitable to 65 percent, and .0502(d) adds required soil depth by the formula SD = MSD + (TW × S), so a 36-inch trench on a 30 percent slope needs roughly 10.8 inches more soil depth than the 18-inch minimum.

2-Story Barndominium: common questions

8 questions we get asked most often about this footprint. If yours is not on the list, ask it directly.

How tall can a two-storey barndominium be in North Carolina?
That is a zoning question and the answer changes at the county line. Davidson County's Table of Dimensional Requirements caps building height in the RA districts at 35 feet. Iredell County caps A-C Agricultural Conservation and R-A Residential Agricultural at 35 feet. Stokes County caps at 35 feet, as does Madison County alongside a 20 percent lot coverage limit. Cabarrus County allows 40 feet in Agricultural/Open Space and Countryside Residential. Sampson County's Residential Agricultural district allows 40 feet. Henderson County's rural district sets no maximum height at all, and its 15-foot accessory height cap does not apply on lots of one acre or more. Two storeys plus a tall bay with an equipment door approaches 35 feet faster than most people expect, so the number to check is the district's, before the elevation is finalised.
Does going up help with lot coverage rules?
Yes, and that is usually the strongest reason to stack. Robeson County's Residential-Agricultural district caps lot coverage by the principal building and all accessory buildings together at twenty percent, on a 20,000 square foot minimum per dwelling unit. Stokes County caps lot coverage by the principal building at 20 percent of the total area. Madison County caps at 20 percent on a one-acre minimum. Cabarrus County caps impermeable surface at 15 percent in Agricultural/Open Space. Buncombe County's steep-slope standards cap gross site area disturbance at 0.3 acres on lots under 2.0 acres and 15 percent on larger lots, and impervious surface at 0.16 acres or 8 percent, with drives, utilities and stormwater controls counting alongside the building. A barndominium is a large slab with a drive and a turnaround attached, so it concentrates more of its area in one place than a stacked plan of the same floor area does.
Does a second storey change the design wind speed?
Not the county figure. The 2018 edition publishes ultimate design wind speed by county in Table R301.2(4), and 51 counties are unlisted and take the 115 mph default, including Wake, Mecklenburg, Guilford, Forsyth, Iredell and Davidson Counties. Table R301.2(4) names Johnston County and Harnett County at 120 mph, splits Cumberland County at I-95 into 120 mph west and 130 mph east, and gives Carteret County 150 mph. In twelve counties — Alleghany, Ashe, Avery, Buncombe, Graham, Haywood, Jackson, Madison, Mitchell, Swain, Watauga and Yancey — Table R301.2(5) sets the speed from the building's first-floor finish elevation instead, and a second storey does not raise the first floor. What a second storey can change is eave height, and that matters for R905.2.6, which requires six fasteners per asphalt strip shingle where the county figure is 130 mph or more and the eave is 20 feet or more above grade.
Is a two-storey post-frame or steel building harder to engineer?
It has more to detail, and the code says why. Section R301.2.1 requires a continuous load path to transmit the applicable uplift forces from the roof assembly to the foundation. On a stacked frame that path runs through the upper columns, the floor diaphragm and its rim condition, and then the lower columns to the footing, and each transition is a connection someone has to design. Section R301.1.2 states that the code's requirements are based on platform and balloon-frame construction and that other framing systems must have equivalent detailing to ensure force transfer, continuity and compatible deformations, which is where a post-frame or steel frame sits. Section R301.1.3 then permits engineered design for the elements exceeding the prescriptive limits, or whole-building design to the International Building Code. § 83A-13(c)(1) exempts a family residence from the architect requirement, but § 89C-25 carries no equivalent residential carve-out for engineering.
Does the upstairs count toward the permit fee?
In most counties yes, and how much depends on the basis. Wake County charges $75 plus $0.25 per square foot of gross floor area, and its schedule defines that area as everything finished within the inside perimeter of the exterior walls with no deduction for garage, corridors, stairs or closets — so the upper hallway and the stair are inside the base. Guilford County charges $150 plus $0.35 per heated square foot, so a heated second storey is billed and an unheated bay is not. Union County charges $0.84 per square foot on area under roof, heated or unheated. Wilkes County prices heated area in brackets, from $0.20 per square foot at 1,000 to 2,499 square feet up to $0.36 at 10,000 and over, so a second floor can move the whole building into a higher bracket. Gaston County sets a $990 minimum and computes from ICC construction valuation or the stated contract price, whichever is greater, so extra floor area arrives as valuation rather than as square feet.
Do bedrooms upstairs change the septic system?
The count does, and the floor they sit on does not. Under 15A NCAC 18E the county health department evaluates the soil and site and, if it classifies the site suitable, issues an Improvement Permit fixing the design daily flow, the bedroom count, the setbacks and the location of both the initial dispersal field and the repair area. Guilford County charges the residential soil evaluation at $100 per bedroom, and its permit guidance requires the bedroom count on the plans to match the permit application and the septic design, with an amendment when it changes. Chatham County prices the Improvement Permit from $150 at two bedrooms to $400 at six. Cabarrus County prices the Construction Authorization by design flow: $350 at 360 gallons per day or less for one to three bedrooms, $450 at 600 gpd or less for four to five, $550 above that. Johnston County's checklist warns specifically that the bedrooms on the septic permit have to match the bedrooms in the residence — the trap on a plan with a bonus room over the shop.
Can I put the shop up first and add the two-storey house later?
Only where the county says so, and it is written differently in each. Sampson County's Residential Accessory Structure Site Plan Requirements permit an accessory structure with no principal dwelling only in the Residential Agricultural district on five acres or more; below five acres, or in another district, the principal structure has to exist first. Stanly County's amendment ZA21-07 permits one barn or shed as the primary structure on RA parcels over three acres, capped at 2,500 square feet and held to the district's primary-structure setbacks. The farm-building route does not solve it either: § 143-138(b4)(1) defines a farm building as a nonresidential building or structure, so a dwelling is outside that exemption from the start, and § 160D-903(a) grants the farm-residence zoning exemption only to a residence constructed to the applicable residential building code. Separately, on well and septic, 15A NCAC 18E .0201(c) provides that the building permit follows the Construction Authorization, so the health department sets the start date either way.
Which design figures are the same everywhere, and which are not?
Under the 2018 edition, which is the one in force, the roof load is a flat 20 psf statewide, weathering is Moderate, frost line depth is 12 inches and termite is Moderate-Heavy with protection required in all of North Carolina under Section R318. There is no ground snow load column in the code at all — Section R301.2.3 is deleted — so no county snow load exists and none should be quoted. Section R403.3, frost-protected shallow foundations, is deleted, so footings go below the 12-inch frost line except on solid rock. Winter design temperature, ice barrier underlayment, flood hazard, air freezing index and mean annual temperature are all given as Local, with no state value. Wind and seismic are the two that vary and they are published county by county in Tables R301.2(4) and R301.2(7) — under the 2018 lists, Brunswick, Columbus, Robeson and Scotland Counties carry Seismic Design Category C alongside nine mountain counties, and the 2024 edition, adopted but with no effective date, removes those four.

Want this drawn for your program and your parcel? That is where a build actually starts.

Start your plans